We ship from multiple warehouses throughout the USA
to get you what you need as fast as possible!
Millions of items in stock!
Fast online checkout - No account required
Cart 0

Lighting & Electrical > Contactors & Starters (ET04) - (4055 Products)

Lighting & Electrical > Contactors & Starters (ET04)

Schneider Electric - Starter Control Unit - For Use with LUFC00, LUFDA01, LUFDA10, LUFDH11, LUFN, LUFV2, LUFW10


Item #: 56829484
Brand: Schneider Electric
Model #: LUCB18ES
Exact Tooling IR#: 04

Product Specifications
Starter Accessory Type Control Unit
For Use With LUFC00; LUFDA01; LUFDA10; LUFDH11; LUFN; LUFV2; LUFW10

$232.35

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - Starter Heater - For Use with MS Starters


Item #: 01259852
Brand: Eaton Cutler-Hammer
Model #: MSH2-5A
Exact Tooling IR#: 04

Product Specifications
Starter Accessory Type Heater
For Use With MS Starters

$73.27

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 3 Pole, 110 VAC at 50 Hz, 120 VAC at 60 Hz and 600 Volt, 18 Continuous Amp, 1 hp, Open NEMA Combination Starter - ABS Type Approved, cUL Listed, NEMA ICS 2-1993, UL Listed


Item #: 02353142
Brand: Eaton Cutler-Hammer
Model #: CN15BN3AB
Exact Tooling IR#: 04

Features and Benefits

National Electrical Manufacturers' Association (NEMA) starters are electrically controlled switches used to rapidly open (break) and close (make) a circuit. They are larger than the International Electrotechnical Commission (IEC) starters and are considred more rugged and durable.
Open housings are designed to disconnect the motor from the line at the time of starting or stopping of equipment. Ideal for inertial loads and they are finger safe.
Single or three-phase refers to either a single coil or three individual coils that connect to and run voltage through the connector. Single-phase lines are used for light-to-medium operations and three-phase lines are used for medium-to-heavy operations.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Product Specifications
Continuous Amperage 18
Starter Type NEMA
Enclosure Type Open
Compatible Motor Phase Single Phase, Three Phase
Action NonReversible
Voltage 110 VAC @ 50 Hz; 120 VAC @ 60 Hz; 600 V
Number of Poles 3
Horsepower (HP) 1
Overall Height (mm) 98.60
Overall Height (Decimal Inch) 3.8800
Overall Width (Decimal Inch) 1-3/4
Overall Width (mm) 44-1/2
Overall Depth (mm) 88.60
Overall Depth (Decimal Inch) 3.4900
Standards Met ABS Type Approved; cUL Listed; NEMA ICS 2-1993; UL Listed

$760.89

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 37 to 50 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10A, For Use with LC1D80 and LC1D95


Item #: 69975571
Brand: Schneider Electric
Model #: LRD3357
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D80; LC1D95
Voltage 690 VAC
Maximum Overload (A) 50
Sensing Method Thermal
Minimum Overload (A) 37
Trip Class 10A
Overall Height (mm) 123
Overall Width (mm) 121
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; RoHS Compliant; UL 508

$160.77

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - Starter Communication Module - For Use with LUCA, LUCB, LUCC, LUCD, LUCL, LUCM


Item #: 54524210
Brand: Schneider Electric
Model #: LULC08
Exact Tooling IR#: 04

Product Specifications
Starter Accessory Type Communication Module
For Use With LUCA; LUCB; LUCC; LUCD; LUCL; LUCM

$328.35

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 30 to 50 Amp, 1,000 VAC, Thermal IEC Overload Relay - Trip Class 20, For Use with LC1F115 and LC1F185


Item #: 56805609
Brand: Schneider Electric
Model #: LR9F5557
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1F115; LC1F185
Voltage 1000 VAC
Maximum Overload (A) 50
Sensing Method Thermal
Minimum Overload (A) 30
Trip Class 20
Overall Height (mm) 96
Overall Width (mm) 123-1/2
Standards Met EN/IEC 60947-4-1; IEC 60255-17; IEC 60255-8; VDE 0660

$426.63

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Brand: USA Sealing / Part #: ZUSANATSR-119


Item #: 95147856
Brand: USA Sealing
Model #: ZUSANATSR-119

Product Specifications

Cell Type Open
Material Natural Sponge
Thickness (Inch) 1
Length Type Standard
Firmness Soft (5-8 psi)
Shape Rectangle
Backing Type Non-Adhesive
Width (Inch) 12
Length (Inch) 24
Color Black
Hardness Soft
Texture Textured
Grade Standard
Minimum Temperature (Deg F - 3 Decimals) -20.000
Maximum Temperature (F) ( - 0 Decimals) 160.000
Standards MILC-3133; MIL-STD-670; ASTM D1056 1A2
Density (Lb./Cu. Ft.) 26

$94.43

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 3 Pole, NEMA Size 1, 23 to 32 Amp, 690 VAC, Thermal NEMA Overload Relay - Trip Class 20, For Use with LC1D25, LC1D32 and LC1D38


Item #: 69527422
Brand: Schneider Electric
Model #: LRD32L
Exact Tooling IR#: 04

Product Specifications
Starter Type NEMA
NEMA Size 1
For Use With LC1D25; LC1D32; LC1D38
Voltage 690 VAC
Maximum Overload (A) 32
Sensing Method Thermal
Minimum Overload (A) 23
Trip Class 20
Number of Poles 3
Overall Depth (mm) 76.10
Overall Depth (Inch) 3
Overall Width (Decimal Inch) 1.7700
Overall Width (mm) 45
Standards Met ABS; ATEX D 94/9/CE; ATEX INERIS; CSA; CSA C22.2 No. 14; EAC; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL; UL 508

$90.55

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 3 Poles, 30 Amp, M-1 NEMA, Enclosed Pushbutton Manual Motor Starter - 10 hp at 380 to 575 VAC & 7-1/2 hp at 200 to 230 VAC, CSA, NEMA 1 & UL Listed


Item #: 69524742
Brand: Square D
Model #: 2510MCG3
Exact Tooling IR#: 04

Features and Benefits

National Electrical Manufacturers' Association (NEMA) starters are electrically controlled switches used to rapidly open (break) and close (make) a circuit. They are larger than the International Electrotechnical Commission (IEC) starters and are considred more rugged and durable.
Pushbutton switches are designed to turn electric on or off. It may consist of one or two contact blocks.
Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Product Specifications
Starter Type NEMA
Amperage 30
Operator Type Pushbutton
Enclosure Type Enclosed
NEMA Size M-1
Horsepower (HP) 10 @ 380-575 VAC; 7-1/2 @ 200-230 VAC
Number of Poles 3
Standards Met CSA; NEMA 1; UL Listed

$459.76

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - NEMA Size 2, 600 VAC, Thermal NEMA Overload Relay - For Use with Motor Logic


Item #: 69651180
Brand: Square D
Model #: 9065SF220
Exact Tooling IR#: 04

Product Specifications
Starter Type NEMA
NEMA Size 2
For Use With Motor Logic
Voltage 600 VAC
Sensing Method Thermal

$354.43

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 50 to 65 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10, For Use with 65-72 A Contactors


Item #: 08805400
Brand: Eaton Cutler-Hammer
Model #: XTOB065DC1
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With 65-72 A Contactors
Voltage 690 VAC
Maximum Overload (A) 65
Sensing Method Thermal
Minimum Overload (A) 50
Trip Class 10
Overall Height (Decimal Inch) 3.1200
Overall Height (mm) 79.20
Overall Depth (mm) 102
Overall Depth (Decimal Inch) 4.0200
Overall Width (Decimal Inch) 2.3600
Overall Width (mm) 60
Standards Met ATEX Compliant; CE Marked; CSA Certified; EN/IEC 60947; RoHS Compliant; UL Listed

$221.50

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 16 to 24 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10, For Use with 18-32 A Contactors


Item #: 08805368
Brand: Eaton Cutler-Hammer
Model #: XTOB024CC1
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With 18-32 A Contactors
Voltage 690 VAC
Maximum Overload (A) 24
Sensing Method Thermal
Minimum Overload (A) 16
Trip Class 10
Overall Height (Decimal Inch) 1.8900
Overall Height (mm) 48
Overall Depth (mm) 83
Overall Depth (Decimal Inch) 3.2700
Overall Width (Decimal Inch) 1.7700
Overall Width (mm) 45
Standards Met ATEX Compliant; CE Marked; CSA Certified; EN/IEC 60947; RoHS Compliant; UL Listed

$174.40

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 70 to 100 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10, For Use with 80-170 A Contactors


Item #: 08805434
Brand: Eaton Cutler-Hammer
Model #: XTOB100GC1
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With 80-170 A Contactors
Voltage 690 VAC
Maximum Overload (A) 100
Sensing Method Thermal
Minimum Overload (A) 70
Trip Class 10
Overall Height (Decimal Inch) 5.4300
Overall Height (mm) 138
Overall Depth (mm) 134
Overall Depth (Decimal Inch) 5.2800
Overall Width (Decimal Inch) 4.6500
Overall Width (mm) 118
Standards Met ATEX Compliant; CE Marked; CSA Certified; EN/IEC 60947; RoHS Compliant; UL Listed

$316.85

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 0.6 to 1 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10, For Use with 7-15 A Contactors


Item #: 08805301
Brand: Eaton Cutler-Hammer
Model #: XTOB001BC1
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With 7-15 A Contactors
Voltage 690 VAC
Maximum Overload (A) 1
Sensing Method Thermal
Minimum Overload (A) 0.60
Trip Class 10
Overall Height (Decimal Inch) 1.8900
Overall Height (mm) 48
Overall Depth (mm) 83
Overall Depth (Decimal Inch) 3.2700
Overall Width (Decimal Inch) 1.7700
Overall Width (mm) 45
Standards Met ATEX Compliant; CE Marked; CSA Certified; EN/IEC 60947; RoHS Compliant; UL Listed

$158.44

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 23 to 32 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10A, For Use with LC1D40A and LC1D65A


Item #: 69527190
Brand: Schneider Electric
Model #: LR3D332
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D40A; LC1D65A
Voltage 690 VAC
Maximum Overload (A) 32
Sensing Method Thermal
Minimum Overload (A) 23
Trip Class 10A
Overall Height (mm) 70
Overall Width (mm) 123
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 508

$165.23

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - NEMA Size 2, 600 VAC, Thermal NEMA Overload Relay


Item #: 56812621
Brand: Square D
Model #: 9065SEO8S1
Exact Tooling IR#: 04

Product Specifications

NEMA Size 2, 600 VAC, Thermal NEMA Overload Relay -
Starter Type NEMA
NEMA Size 2
Voltage 600 VAC
Sensing Method Thermal

$274.33

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 30 to 40 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10A, For Use with LC1D40A and LC1D65A


Item #: 69648400
Brand: Schneider Electric
Model #: LR3D340
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D40A; LC1D65A
Voltage 690 VAC
Maximum Overload (A) 40
Sensing Method Thermal
Minimum Overload (A) 30
Trip Class 10A
Overall Height (mm) 70
Overall Width (mm) 123
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 508

$169.88

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 3 Pole, 18 Amp, 208 Coil VAC, 50/60 Hz, Nonreversible Enclosed IEC Motor Starter - 1 Phase Hp: 1 at 115 Volt, 3 at 230 V Volt, 3 Phase Hp: 10 at 460 Volt, 15 at 575 Volt, 5 at 200 Volt, 5 at 230 VAC


Item #: 56829245
Brand: Schneider Electric
Model #: LE1D183A62OL70
Exact Tooling IR#: 04

Features and Benefits

International Electrotechnical Commission (IEC) motor starters are contactors with overload relays and used for turning an electrical motor on/off, reversing motion and providing protection for overloads in electrical equipment. They are similar to National Electrical Manufacturers' Association (NEMA) motor starters, but are smaller in size and quicker to find detection of overload conditions.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Product Specifications
Starter Type IEC
Amperage 18
Coil Voltage 208 VAC
Action NonReversible
Auxiliary Contact Configuration NC/NO
Horsepower at 3 Phase 10 @ 460 V; 15 @ 575 V; 5 @ 200 V; 5 @ 230 VAC
Horsepower at 1 Phase 1 @ 115 V; 3 @ 230 V
Enclosure Type Enclosed
Number of Poles 3
Frequency Rating (Hz) 50/60
Overall Height (mm) 255
Overall Height (Decimal Inch) 10.0400
Overall Width (mm) 172
Overall Width (Decimal Inch) 6.7700
Overall Depth (mm) 158
Overall Depth (Decimal Inch) 6-1/4
Standards Met CSA File No. LR23506 41 Class 3211 04; UL E154118 CCN NLDX CCN NLDX7

$250.77

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 9 to 12 Amp, 690 VAC, IEC Overload Relay - Trip Class 10


Item #: 08805509
Brand: Eaton Cutler-Hammer
Model #: XTOM012AC1
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
Voltage 690 VAC
Maximum Overload (A) 12
Minimum Overload (A) 9
Trip Class 10
Standards Met ATEX Compliant; CCC; CE Marked; CSA Certified; EN/IEC 60947; RoHS Compliant; UL Listed; VDE 0660

$84.38

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 1 to 1.6 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10A, For Use with LC1D09 and LC1D38


Item #: 54422159
Brand: Schneider Electric
Model #: LR3D06
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D09; LC1D38
Voltage 690 VAC
Maximum Overload (A) 1.60
Sensing Method Thermal
Minimum Overload (A) 1
Trip Class 10A
Overall Width (mm) 70
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 508

$85.41

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It