We ship from multiple warehouses throughout the USA
to get you what you need as fast as possible!
Millions of items in stock!
Fast online checkout - No account required
Cart 0

Lighting & Electrical > Contactors & Starters (ET04) - (4055 Products)

Lighting & Electrical > Contactors & Starters (ET04)

Schneider Electric - Starter Control Unit - For Use with ASILUFC5, ASILUFC51, LUFC00, LUFN


Item #: 49786973
Brand: Schneider Electric
Model #: LUCAX6BL
Exact Tooling IR#: 04

Product Specifications
Starter Accessory Type Control Unit
For Use With ASILUFC5; ASILUFC51; LUFC00; LUFN

$146.45

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Cooper Wiring Devices - 3 Poles, 30 Amp, 3PST, NEMA, Enclosed Manual Motor Starter - 66.8mm Wide x 118.62mm Deep x 112.27mm High, 15 hp at 480 V, 15 hp at 600 V, 3 hp at 120 V & 7-1/2 hp at 240 V, CSA C22.2 No. 14, NEMA 1 & UL 508


Item #: 78006616
Brand: Cooper Wiring Devices
Model #: AH7810GD
Exact Tooling IR#: 04

Features and Benefits

National Electrical Manufacturers' Association (NEMA) starters are electrically controlled switches used to rapidly open (break) and close (make) a circuit. They are larger than the International Electrotechnical Commission (IEC) starters and are considred more rugged and durable.
Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Product Specifications
Starter Type NEMA
Amperage 30
Enclosure Type Enclosed
Horsepower (HP) 15 @ 480 V; 15 @ 600 V; 3 @ 120 V; 7-1/2 @ 240 V
Number of Poles 3
Contact Form 3PST
Overall Height (mm) 112.27
Overall Height (Decimal Inch) 4.4200
Overall Width (mm) 66.80
Overall Width (Decimal Inch) 2.6300
Overall Depth (mm) 118.62
Overall Depth (Decimal Inch) 4.6700
Standards Met CSA C22.2 No. 14; NEMA 1; UL 508

$161.46

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 17 to 25 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 20, For Use with LC1D40A and LC1D65A


Item #: 69527430
Brand: Schneider Electric
Model #: LRD325L
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D40A; LC1D65A
Voltage 690 VAC
Maximum Overload (A) 25
Sensing Method Thermal
Minimum Overload (A) 17
Trip Class 20
Overall Height (mm) 70
Overall Width (mm) 123
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; RoHS Compliant; UL 508

$144.08

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 3 Poles, 30 Amp, NEMA, Enclosed Toggle Manual Motor Starter - 1 hp at 90 VDC, 10 hp at 460 VAC, 10 hp at 575 VAC, 1-1/2 hp at 230 VDC, 2 hp at 115 VAC, 2 hp at 115 VDC & 7-1/2 hp at 230 VAC, CE, CSA, NEMA 4 & UL Listed


Item #: 69524775
Brand: Square D
Model #: 2510KW2H
Exact Tooling IR#: 04

Features and Benefits

National Electrical Manufacturers' Association (NEMA) starters are electrically controlled switches used to rapidly open (break) and close (make) a circuit. They are larger than the International Electrotechnical Commission (IEC) starters and are considred more rugged and durable.
Toggle switches are designed for safety and speed of an operation. They closes or open contacts with a lever.
Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Product Specifications
Starter Type NEMA
Amperage 30
Operator Type Toggle
Enclosure Type Enclosed
Horsepower (HP) 1 @ 90 VDC; 10 @ 460 VAC; 10 @ 575 VAC; 1-1/2 @ 230 VDC; 2 @ 115 VAC; 2 @ 115 VDC; 7-1/2 @ 230 VAC
Number of Poles 3
Standards Met CE; CSA; NEMA 4; UL Listed

$520.58

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 32 Amp, 50/60 Hz, IEC Motor Starter - 3 Phase Hp: 20


Item #: 69681096
Brand: Schneider Electric
Model #: ATS01N232RT
Exact Tooling IR#: 04

Features and Benefits

Soft starters, also known as RVS (Reduced Voltage Starting), is generally used with large horsepower motors to reduce the inrush current and limit the torque output that can cause mechanical stress on the load.
Product Specifications
Starter Type Soft Starter
Amperage 32
Horsepower at 3 Phase 20
Frequency Rating (Hz) 50/60
Overall Height (mm) 154
Overall Height (Decimal Inch) 6.0600
Overall Width (mm) 45
Overall Width (Decimal Inch) 1.7700
Overall Depth (mm) 131
Overall Depth (Decimal Inch) 5.1600
Standards Met B44.1-96/ASME A17.5; CCC; CE; CSA; C-Tick; EN/IEC 60947-4-2; GOST; IEC 61000-4-5 Level 3; RoHS Compliant; UL

$418.08

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 2.6 to 3.7 Amp, 250 VDC, 690 Volt and 690 VAC, Thermal IEC Overload Relay - Trip Class 10A, For Use with LC1K, LC7K, LP1K and LP4K


Item #: 37302296
Brand: Schneider Electric
Model #: LR2K0310
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1K; LC7K; LP1K; LP4K
Voltage 250 VDC; 690 V; 690 VAC
Maximum Overload (A) 3.70
Sensing Method Thermal
Minimum Overload (A) 2.60
Trip Class 10A
Overall Height (mm) 58
Overall Width (mm) 65
Standards Met BS 4941; IEC 60947; NF C 63-650; VDE 0660

$93.99

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Brand: DoALL / Part #: 381-334200.000


Item #: 97744213
Brand: DoALL
Model #: 381-334200.000

Product Specifications

Blade Length (Feet) 16' 8"
Blade Material Bi-Metal
Teeth Per Inch 3-4
Blade Width (Inch) 1-1/4
Blade Thickness (Decimal Inch) 0.0420
Cutting Edge Style Toothed
Tooth Set Ground Tooth
Tooth Material M 51 HSS
Tooth Form Positive
Pitch Pattern Variable
Contour Cutting No
Material Application Exotic Steel

$149.87

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Springer - 8 to 12 Amp, IEC Overload Relay - Trip Class 10, For Use with 9-32A JC Contactors


Item #: 54096193
Brand: Springer
Model #: JL1-N
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With 9-32A JC Contactors
Maximum Overload (A) 12
Minimum Overload (A) 8
Trip Class 10
Overall Height (Decimal Inch) 3.3800
Overall Height (mm) 85.80
Overall Depth (mm) 107.70
Overall Depth (Decimal Inch) 4.2400
Overall Width (Decimal Inch) 1.7700
Overall Width (mm) 45

$152.69

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Springer - 0.65 to 1.1 Amp, IEC Overload Relay - Trip Class 10, For Use with 9-32A JC Contactors


Item #: 54096128
Brand: Springer
Model #: JL1-F
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With 9-32A JC Contactors
Maximum Overload (A) 1.10
Minimum Overload (A) 0.65
Trip Class 10
Overall Height (Decimal Inch) 3.3800
Overall Height (mm) 85.80
Overall Depth (mm) 107.70
Overall Depth (Decimal Inch) 4.2400
Overall Width (Decimal Inch) 1.7700
Overall Width (mm) 45

$78.76

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - Starter Heater - For Use with A200/B100 Starter Size 2


Item #: 02354983
Brand: Eaton Cutler-Hammer
Model #: FH57
Exact Tooling IR#: 04

Product Specifications
Starter Accessory Type Heater
For Use With A200/B100 Starter Size 2

$84.93

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 3 Pole, 12 Amp, 24 Coil VAC, Nonreversible Enclosed IEC Motor Starter - 1 Phase Hp: 0.5 at 120 VAC, 2 at 240 VAC, 3 Phase Hp: 10 at 575 VAC, 3 at 208 VAC, 3 at 230 VAC, 7.5 at 460 VAC


Item #: 49787047
Brand: Schneider Electric
Model #: LE1D123A62OB70
Exact Tooling IR#: 04

Features and Benefits

Enclosed full voltage starters connect the incoming power directly to the motor and are used in applications where the motor runs in only one direction and speed.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Product Specifications
Starter Type Enclosed Full Voltage Starter
Amperage 12
Coil Voltage 24 VAC
Action NonReversible
Auxiliary Contact Configuration NC/NO
Horsepower at 3 Phase 10 @ 575 VAC; 3 @ 208 VAC; 3 @ 230 VAC; 7.5 @ 460 VAC
Horsepower at 1 Phase 0.5 @ 120 VAC; 2 @ 240 VAC
Enclosure Type Enclosed
Number of Poles 3
Standards Met CSA; IEC; NEMA 1; UL

$225.49

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - Overload Relays Starter Type: IEC NEMA Size: 00-1


Item #: 55942130
Brand: Schneider Electric
Model #: LR9D32
Exact Tooling IR#: 04

Product Specifications

Overload Relays; Starter Type: IEC ; NEMA Size: 00-1 ; For Use With: LC1D09; LC1D12; LC1D18; LC1D25; LC1D32; LC1D38 ; Voltage: 690 V
Starter Type IEC
NEMA Size 00-1
For Use With LC1D09; LC1D12; LC1D18; LC1D25; LC1D32; LC1D38
Voltage 690 V

$101.77

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 2 Poles, 0.4 to 16 Amp, NEMA, Open Toggle Manual Motor Starter - 43.2mm Wide x 40.1mm Deep x 96.8mm High, 1 hp at 120/240 V, 1 hp at 277 V & 1/4 hp at 32 V, CSA Certified & UL Listed


Item #: 01259670
Brand: Eaton Cutler-Hammer
Model #: MST02
Exact Tooling IR#: 04

Features and Benefits

National Electrical Manufacturers' Association (NEMA) starters are electrically controlled switches used to rapidly open (break) and close (make) a circuit. They are larger than the International Electrotechnical Commission (IEC) starters and are considred more rugged and durable.
Amperage refers to the maximum electrical current the product is intended to accommodate.
Toggle switches are designed for safety and speed of an operation. They closes or open contacts with a lever.
Open housings are designed to disconnect the motor from the line at the time of starting or stopping of equipment. Ideal for inertial loads and they are finger safe.
Product Specifications
Starter Type NEMA
Amperage 0.40-16
Operator Type Toggle
Enclosure Type Open
Horsepower (HP) 1 @ 120/240 V; 1 @ 277 V; 1/4 @ 32 V
Number of Poles 2
Overall Height (mm) 96.80
Overall Height (Decimal Inch) 3.8100
Overall Width (mm) 43.20
Overall Width (Decimal Inch) 1.7000
Overall Depth (mm) 40.10
Overall Depth (Decimal Inch) 1.5800
Standards Met CSA Certified; UL Listed

$200.70

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 3 Pole, 12 Amp, 120 Coil VAC, Nonreversible Enclosed IEC Motor Starter - 1 Phase Hp: 0.5 at 120 VAC, 2 at 240 VAC, 3 Phase Hp: 10 at 575 VAC, 3 at 208 VAC, 3 at 230 VAC, 7.5 at 460 VAC


Item #: 69665164
Brand: Schneider Electric
Model #: LE1D123A62OG70
Exact Tooling IR#: 04

Features and Benefits

Enclosed full voltage starters connect the incoming power directly to the motor and are used in applications where the motor runs in only one direction and speed.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Product Specifications
Starter Type Enclosed Full Voltage Starter
Amperage 12
Coil Voltage 120 VAC
Action NonReversible
Auxiliary Contact Configuration NC/NO
Horsepower at 3 Phase 10 @ 575 VAC; 3 @ 208 VAC; 3 @ 230 VAC; 7.5 @ 460 VAC
Horsepower at 1 Phase 0.5 @ 120 VAC; 2 @ 240 VAC
Enclosure Type Enclosed
Number of Poles 3
Standards Met CSA; IEC; NEMA 1; UL

$225.49

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 48 to 65 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10A, For Use with LC1D50A and LC1D65A


Item #: 56829088
Brand: Schneider Electric
Model #: LRD3656
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D50A; LC1D65A
Voltage 690 VAC
Maximum Overload (A) 65
Sensing Method Thermal
Minimum Overload (A) 48
Trip Class 10A
Overall Height (mm) 70
Overall Width (mm) 123
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; RoHS Compliant; UL 508

$175.74

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 48 to 65 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10A, For Use with LC1D50A and LC1D65A


Item #: 59032672
Brand: Schneider Electric
Model #: LRD365
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D50A; LC1D65A
Voltage 690 VAC
Maximum Overload (A) 65
Sensing Method Thermal
Minimum Overload (A) 48
Trip Class 10A
Overall Height (mm) 70
Overall Width (mm) 123
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; RoHS Compliant; UL 508

$158.03

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - NEMA Size 3, 600 VAC, Thermal NEMA Overload Relay


Item #: 54421474
Brand: Square D
Model #: 9065SDO12
Exact Tooling IR#: 04

Product Specifications

NEMA Size 3, 600 VAC, Thermal NEMA Overload Relay -
Starter Type NEMA
NEMA Size 3
Voltage 600 VAC
Sensing Method Thermal
Standards Met CE; CSA; UL Listed

$283.79

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 9 Amp, 120 Coil VAC, 50/60 Hz, IEC Motor Starter - 3 Phase Hp: 5


Item #: 69681112
Brand: Schneider Electric
Model #: ATS01N209RT
Exact Tooling IR#: 04

Features and Benefits

Soft starters, also known as RVS (Reduced Voltage Starting), is generally used with large horsepower motors to reduce the inrush current and limit the torque output that can cause mechanical stress on the load.
Product Specifications
Starter Type Soft Starter
Amperage 9
Coil Voltage 120 VAC
Horsepower at 3 Phase 5
Frequency Rating (Hz) 50/60
Overall Height (mm) 124
Overall Height (Decimal Inch) 4.8800
Overall Width (mm) 45
Overall Width (Decimal Inch) 1.7700
Overall Depth (mm) 131
Overall Depth (Decimal Inch) 5.1600
Standards Met B44.1-96/ASME A17.5; CCC; CE; CSA; C-Tick; EN/IEC 60947-4-2; GOST; IEC 61000-4-5 Level 3; RoHS Compliant; UL

$215.61

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 380 to 630 Amp, 1,000 VAC, Thermal IEC Overload Relay - Trip Class 20, For Use with LC1F400, LC1F630 and LC1F800


Item #: 56805617
Brand: Schneider Electric
Model #: LR9F7381
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1F400; LC1F630; LC1F800
Voltage 1000 VAC
Maximum Overload (A) 630
Sensing Method Thermal
Minimum Overload (A) 380
Trip Class 20
Overall Height (mm) 127.60
Overall Width (mm) 136.80
Standards Met EN/IEC 60947-4-1; IEC 60255-17; IEC 60255-8; VDE 0660

$1,412.25

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Brand: Ingersoll Cutting Tools / Part #: 4209971


Item #: 50143700
Brand: Ingersoll Cutting Tools
Model #: 4209971

Product Specifications

Maximum Drill Diameter (mm) 23.30
Point Angle 140.00
Diameter (mm) 23.3000
Tip Material Solid Carbide
Manufacturer Grade IN2505
Cutting Direction Right Hand
Series TKA
Coating Process PVD
Insert Geometry K
Insert Seat Size 23
Primary Workpiece Material Cast Iron
Primary Workpiece Material Code K
Height (mm) 13.3400
Head Length (mm) 13.34
Cutting Diameter (mm) 23.30
Drill Point Angle 140
Flute Type Helical
Insert Holding Method Twist
ISO Number TKA2330R01 IN2505
Coolant Through Yes
Flute Length (mm) 7.82
Point Type Spiral Point
Overall Length/Projection (mm) 13.34
Spiral Type Regular
Style TKA
Coating Classification PVD
Applications Drilling
Coating/Finish TiN; TiAlN
Included Angle Degree 140
Number Of Flutes 2

$151.47

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It