We ship from multiple warehouses throughout the USA
to get you what you need as fast as possible!
Millions of items in stock!
Fast online checkout - No account required
Cart 0

Products - (25001 Products)


Schneider Electric - 12 to 18 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10A, For Use with LC1D18 and LC1D38


Item #: 56828999
Brand: Schneider Electric
Model #: LR3D216
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D18; LC1D38
Voltage 690 VAC
Maximum Overload (A) 18
Sensing Method Thermal
Minimum Overload (A) 12
Trip Class 10A
Overall Width (mm) 70
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 508

$128.05

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 12 to 18 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10A, For Use with LC1D18 and LC1D38


Item #: 56805377
Brand: Schneider Electric
Model #: LRD216
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D18; LC1D38
Voltage 690 VAC
Maximum Overload (A) 18
Sensing Method Thermal
Minimum Overload (A) 12
Trip Class 10A
Overall Width (mm) 70
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; RoHS Compliant; UL 508

$128.05

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 12 to 18 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10A, For Use with LC1D18 and LC1D38


Item #: 69648418
Brand: Schneider Electric
Model #: LR3D21
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D18; LC1D38
Voltage 690 VAC
Maximum Overload (A) 18
Sensing Method Thermal
Minimum Overload (A) 12
Trip Class 10A
Overall Width (mm) 70
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 508

$87.20

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 12 to 18 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10A, For Use with LC1D40A and LC1D65A


Item #: 54525431
Brand: Schneider Electric
Model #: LRD318
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D40A; LC1D65A
Voltage 690 VAC
Maximum Overload (A) 18
Sensing Method Thermal
Minimum Overload (A) 12
Trip Class 10A
Overall Height (mm) 70
Overall Width (mm) 123
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; RoHS Compliant; UL 508

$152.30

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 12 to 18 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 20, For Use with LC1D40A and LC1D65A


Item #: 56829096
Brand: Schneider Electric
Model #: LRD318L
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D40A; LC1D65A
Voltage 690 VAC
Maximum Overload (A) 18
Sensing Method Thermal
Minimum Overload (A) 12
Trip Class 20
Overall Height (mm) 70
Overall Width (mm) 123
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; RoHS Compliant; UL 508

$175.74

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 120 Coil VAC, 18 Amp, Nonreversible Open Enclosure NEMA Motor Starter - 3 Phase hp: 3 at 200 VAC, 3 at 230 VAC, 5 at 460 VAC, 5 at 575 VAC


Item #: 56823792
Brand: Schneider Electric
Model #: T36BN13G7
Exact Tooling IR#: 04

Features and Benefits

Open housings are designed to disconnect the motor from the line at the time of starting or stopping of equipment. Ideal for inertial loads and they are finger safe.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Open - no enclosures are starters without a protective enclosure.
Product Specifications
Amperage 18
NEMA Size 0
Coil Voltage 120 VAC
Enclosure Type Open
Action NonReversible
NEMA Enclosure Rating Open - No Enclosure
Horsepower at 3 Phase 3 @ 200 VAC; 3 @ 230 VAC; 5 @ 460 VAC; 5 @ 575 VAC
Standards Met CE; CSA; UL Listed

$506.62

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 120 Coil VAC, 27 Amp, NEMA Size 1, Nonreversible Open Enclosure NEMA Motor Starter - 3 Phase hp: 10 at 460 VAC, 10 at 575 VAC, 7-1/2 at 200 VAC, 7-1/2 at 230 VAC


Item #: 56814999
Brand: Schneider Electric
Model #: T36CN13G7
Exact Tooling IR#: 04

Features and Benefits

Open housings are designed to disconnect the motor from the line at the time of starting or stopping of equipment. Ideal for inertial loads and they are finger safe.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Open - no enclosures are starters without a protective enclosure.
Product Specifications
Amperage 27
NEMA Size 1
Coil Voltage 120 VAC
Enclosure Type Open
Action NonReversible
NEMA Enclosure Rating Open - No Enclosure
Horsepower at 3 Phase 10 @ 460 VAC; 10 @ 575 VAC; 7-1/2 @ 200 VAC; 7-1/2 @ 230 VAC
Standards Met CE; CSA; UL Listed

$604.19

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 120 Coil VAC, 270 Amp, NEMA Size 5, Nonreversible Open Enclosure NEMA Motor Starter - 3 Phase hp: 100 at 230 VAC, 200 at 460 VAC, 200 at 575 VAC, 75 at 200 VAC


Item #: 56813520
Brand: Schneider Electric
Model #: T36GN13G7
Exact Tooling IR#: 04

Features and Benefits

Open housings are designed to disconnect the motor from the line at the time of starting or stopping of equipment. Ideal for inertial loads and they are finger safe.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Open - no enclosures are starters without a protective enclosure.
Product Specifications
Amperage 270
NEMA Size 5
Coil Voltage 120 VAC
Enclosure Type Open
Action NonReversible
NEMA Enclosure Rating Open - No Enclosure
Horsepower at 3 Phase 100 @ 230 VAC; 200 @ 460 VAC; 200 @ 575 VAC; 75 @ 200 VAC
Standards Met CE; CSA; UL Listed

$8,531.13

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 120 Coil VAC, 45 Amp, NEMA Size 2, Nonreversible Open Enclosure NEMA Motor Starter - 3 Phase hp: 10 at 200 VAC, 15 at 230 VAC, 25 at 460 VAC, 25 at 575 VAC


Item #: 56824469
Brand: Schneider Electric
Model #: T36DN13G7S
Exact Tooling IR#: 04

Features and Benefits

Open housings are designed to disconnect the motor from the line at the time of starting or stopping of equipment. Ideal for inertial loads and they are finger safe.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Open - no enclosures are starters without a protective enclosure.
Product Specifications
Amperage 45
NEMA Size 2
Coil Voltage 120 VAC
Enclosure Type Open
Action NonReversible
NEMA Enclosure Rating Open - No Enclosure
Horsepower at 3 Phase 10 @ 200 VAC; 15 @ 230 VAC; 25 @ 460 VAC; 25 @ 575 VAC
Standards Met CE; CSA; UL Listed

$1,214.23

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 120 Coil VAC, 45 Amp, NEMA Size 2, Nonreversible Open Enclosure NEMA Motor Starter - 3 Phase hp: 10 at 200 VAC, 15 at 230 VAC, 25 at 460 VAC, 25 at 575 VAC


Item #: 56814445
Brand: Schneider Electric
Model #: T36DN13G7
Exact Tooling IR#: 04

Features and Benefits

Open housings are designed to disconnect the motor from the line at the time of starting or stopping of equipment. Ideal for inertial loads and they are finger safe.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Open - no enclosures are starters without a protective enclosure.
Product Specifications
Amperage 45
NEMA Size 2
Coil Voltage 120 VAC
Enclosure Type Open
Action NonReversible
NEMA Enclosure Rating Open - No Enclosure
Horsepower at 3 Phase 10 @ 200 VAC; 15 @ 230 VAC; 25 @ 460 VAC; 25 @ 575 VAC
Standards Met CE; CSA; UL Listed

$1,214.23

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 120 Coil VAC, 9 Amp, Nonreversible Open Enclosure NEMA Motor Starter - 3 Phase hp: 1-1/2 at 200 VAC, 1-1/2 at 230 VAC, 2 at 460 VAC, 2 at 575 VAC


Item #: 56816374
Brand: Schneider Electric
Model #: T36AN13G7
Exact Tooling IR#: 04

Features and Benefits

Open housings are designed to disconnect the motor from the line at the time of starting or stopping of equipment. Ideal for inertial loads and they are finger safe.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Open - no enclosures are starters without a protective enclosure.
Product Specifications
Amperage 9
NEMA Size 00
Coil Voltage 120 VAC
Enclosure Type Open
Action NonReversible
NEMA Enclosure Rating Open - No Enclosure
Horsepower at 3 Phase 1-1/2 @ 200 VAC; 1-1/2 @ 230 VAC; 2 @ 460 VAC; 2 @ 575 VAC
Standards Met CE; CSA; UL Listed

$412.25

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 120 VAC, 12 Continuous Amp, Enclosed IEC Combination Starter - NEMA 1


Item #: 56805096
Brand: Schneider Electric
Model #: LE1D126B62OG70
Exact Tooling IR#: 04

Features and Benefits

International Electrotechnical Commission (IEC) starts are electrically controlled switches used to rapidly open (break) and close (make) a circuit. Similar to National Electrical Manufacturers' Association (NEMA) starters, IEC starters are much smaller and can provide quicker detection of overload conditions.
Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Product Specifications
Continuous Amperage 12
Starter Type IEC
Enclosure Type Enclosed
Action NonReversible
Voltage 120 VAC
Standards Met NEMA 1

$870.63

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 132 to 220 Amp, 1,000 VAC, Thermal IEC Overload Relay - Trip Class 10, For Use with LC1F185 and LC1F400


Item #: 69648541
Brand: Schneider Electric
Model #: LR9F5371
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1F185; LC1F400
Voltage 1000 VAC
Maximum Overload (A) 220
Sensing Method Thermal
Minimum Overload (A) 132
Trip Class 10
Overall Height (mm) 101
Overall Width (mm) 123-1/2
Standards Met EN/IEC 60947-4-1; IEC 60255-17; IEC 60255-8; VDE 0660

$465.02

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 132 to 220 Amp, 1,000 VAC, Thermal IEC Overload Relay - Trip Class 20, For Use with LC1F185 and LC1F400


Item #: 69527042
Brand: Schneider Electric
Model #: LR9F5571
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1F185; LC1F400
Voltage 1000 VAC
Maximum Overload (A) 220
Sensing Method Thermal
Minimum Overload (A) 132
Trip Class 20
Overall Height (mm) 101
Overall Width (mm) 123-1/2
Standards Met EN/IEC 60947-4-1; IEC 60255-17; IEC 60255-8; VDE 0660

$465.02

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 14124 Amp, Contactor Coil - For Use with LC1D09-D38, LC1DT20-DT40 and TeSys D


Item #: 69527554
Brand: Schneider Electric
Model #: LXD1B7
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Coil
For Use With LC1D09-D38; LC1DT20-DT40; TeSys D
Compatible Contactor Amperage 9-38

$48.98

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 14124 Amp, Contactor Coil - For Use with LC1D09-D38, LC1DT20-DT40 and TeSys D


Item #: 69530921
Brand: Schneider Electric
Model #: LXD1U7
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Coil
For Use With LC1D09-D38; LC1DT20-DT40; TeSys D
Compatible Contactor Amperage 9-38

$48.98

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 14124 Amp, Contactor Coil - For Use with LC1D09-D38, LC1DT20-DT40 and TeSys D


Item #: 56830664
Brand: Schneider Electric
Model #: LXD1Q7
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Coil
For Use With LC1D09-D38; LC1DT20-DT40; TeSys D
Compatible Contactor Amperage 9-38

$47.14

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 16 to 24 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10A, For Use with LC1D25 and LC1D38


Item #: 56805351
Brand: Schneider Electric
Model #: LRD226
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D25; LC1D38
Voltage 690 VAC
Maximum Overload (A) 24
Sensing Method Thermal
Minimum Overload (A) 16
Trip Class 10A
Overall Width (mm) 70
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; RoHS Compliant; UL 508

$96.75

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 16 to 24 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10A, For Use with LC1D25 and LC1D38


Item #: 69527174
Brand: Schneider Electric
Model #: LR3D22
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D25; LC1D38
Voltage 690 VAC
Maximum Overload (A) 24
Sensing Method Thermal
Minimum Overload (A) 16
Trip Class 10A
Overall Width (mm) 70
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 508

$80.99

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 16 to 24 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10A, For Use with LC1D25 and LC1D38


Item #: 69527398
Brand: Schneider Electric
Model #: LRD22
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D25; LC1D38
Voltage 690 VAC
Maximum Overload (A) 24
Sensing Method Thermal
Minimum Overload (A) 16
Trip Class 10A
Overall Width (mm) 70
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; RoHS Compliant; UL 508

$97.82

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It